Validation and Verification of Healthcare Ventilation Systems HTM 03-01 (VVH)

£845 + VAT
3 Days
York and Slough.
Course Overview
This 3 day City & Guilds accredited course has been developed to provide delegates with the necessary understanding of commissioning, validation and verification of ventilation systems in the healthcare environment required by HTM 03-01 and its associated documents. It will give guidance on the physical inspection and measurement of actual performance the systems and the production and understanding of verification reports.
Who is This Course For?
This course has been designed for those contracted to undertake the inspection and measurement of critical systems performance in accordance with the requirements of HTM 03-01.

The course would also benefit healthcare (operations and projects) managers, Authorising Engineer ventilation (AE(V), Authorised Person(s) Ventilation AP(V), those who are required to serve on the multidisciplinary Ventilation safety group (VSG) and technical staff. Those attending the course would find it helpful to have an appreciation of the ventilation strategies encountered on the health estates and the verification procedures outlined in HTM 03-01 for these systems.
Start Date End Date Location Price (Ex. Vat)
Wed, 12th January 2022 Fri, 14th January 2022 York £845
Tue, 22nd February 2022 Thu, 24th February 2022 Slough £845
Wed, 2nd March 2022 Fri, 4th March 2022 York £845

Day Morning Afternoon
One
  • Course Introduction
  • Annual Inspection and Verification Requirements
  • Critical Healthcare Ventilation Systems and Verification Standards
  • Practical Exercise No.1
    Appendix 1: Annual Inspection of Critical Ventilation Systems - AHU and Plantroom Equipment - Visual Inspection
Two
  • Instruments Verification Process Model
  • Practical Exercise No.2
    Appendix 2: Operating Suite Annual Verification - Practical Measurements
  • Practical Exercise No.2
    Appendix 2: Operating Suite Annual Verification - Practical Measurements
  • Evening Exercise
Three
  • Evening Exercise Review
  • Verification Report - Contents and Production
  • Written Assessment
  • Course Closure
  • The Commissioning & Validation Process
  • Annual Verification and Performance Testing;
  • The Measurement of All System Supply and Extract Air-flow Rates
  • The Calculation of Room Air-change Rates If Applicable
  • The Measurement of Room Differential Pressures If Applicable
  • The Measurement of Room Noise Levels
  • Temperature, Humidity and Any Application Specific Air Velocity Measurements
  • A Check of the Control Functions
There are no additional requirements prior to attending this course.